SEC-1075

90

Probable Cause

Indicates a security command was run on a switch that is not allowed to run it either because it is in
non-secure mode or because it does not have the required fabric configuration server (FCS)
privilege.

Recommended

Action

If a security operation that is not allowed in non-secure mode is attempted, do not perform the
operation in non-secure mode. In secure mode, run the command from a switch that has required
privilege, that is, either a backup FCS or primary FCS.

Severity

ERROR

SEC-1075

Message

<timestamp>, [SEC-1075], <sequence-number>,, ERROR, <system-name>, Fail to

<operation> new policy set on all switches.

Probable Cause

Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.

Severity

ERROR

SEC-1076

Message

<timestamp>, [SEC-1076], <sequence-number>,, ERROR, <system-name>,

NoNodeWWNZoning option has been changed.

Probable Cause

Indicates the NoNodeWWNZoning option has been changed. If the option is turned on, a zone
member can be added using node WWNs, but the member will not be able to communicate with
others nodes in the zone.

Recommended

Action

Re-enable the current zone configuration for the change to take effect.

Severity

ERROR

SEC-1077

Message

<timestamp>, [SEC-1077], <sequence-number>,, ERROR, <system-name>, Failed to

activate new policy set on all switches.

Probable Cause

Indicates the policy could not be activated. Possible reasons that the policy could not be activated
include not enough memory or a busy switch.

Recommended

Action

Run the secFabricShow command to verify that all switches in the fabric are in the ready state.
Retry the command when all switches are ready.