Fabric OS Message Reference

53-1001767-01

BL-1034

7

Probable Cause

Indicates that the system has timed out while waiting for disable messages from the user ports
after disabling the ports.

Recommended

Action

Restart or power cycle the blade. Run the systemVerification command to verify that the blade does
not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST)
is enabled. If the message persists, replace the blade.

Refer to the Fabric OS Command Reference for more information on the systemVerification
command.

Severity

CRITICAL

BL-1034

Message

<timestamp>, [BL-1034], <sequence-number>,, INFO, <system-name>, Slot

<slot

number>

FC Initialization completed.

Probable Cause

Indicates that the slot has completed initializing Fibre Channel (FC) ports.

Recommended

Action

No action is required.

Severity

INFO

BL-1035

Message

<timestamp>, [BL-1035], <sequence-number>,, INFO, <system-name>, Slot <slot

number> iSCSI port <iscsi port number> Initialization completed.

Probable Cause

Indicates that the slot has completed initializing the specified iSCSI port.

Recommended

Action

No action is required.

Severity

INFO

BL-1036

Message

<timestamp>, [BL-1036], <sequence-number>,, CRITICAL, <system-name>, Faulting 8G

blade in slot = <slot number> due to incompatible stag mode. All EX/VEX ports must

be disabled in order to enable the 8G blade in the chassis.

Probable Cause

Indicates that the FOS 6.0, 8G blade with legacy mode (EX_port having stag) will be disabled.

Recommended

Action

Disable all EX/VEX ports and perform a slotpoweroff or slotpoweron operation on the 8G blade.
Also, all EX/VEX ports can be re-enabled now.

Severity

CRITICAL