Cvlc-1019, Cvlc-1020, Cvlc-1021 – Dell POWEREDGE M1000E User Manual
Page 204
128
Fabric OS Message Reference
53-1001767-01
CVLC-1019
19
Probable Cause
Indicates an informational event.
Recommended
Action
No action is required.
Severity
INFO
CVLC-1019
Message
<timestamp>, [CVLC-1019], <sequence-number>,, ERROR, <system-name>, Metadata
exists while data state is clear text.\nContainer: <Target container name>,
Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Probable Cause
Indicates that the data state in the LUN configuration is in clear text state but metadata exists on
the LUN.
Recommended
Action
Use cryptocfg command to confirm the configuration.
Severity
ERROR
CVLC-1020
Message
<timestamp>, [CVLC-1020], <sequence-number>,, ERROR, <system-name>, Metadata
exists while LUN is clear text.\nContainer: <Target container name>, Initiator:
<Initiator physical WWN>, LUN ID: <LUN ID>.
Probable Cause
Indicates that metadata exists on the LUN that is clear text.
Recommended
Action
Use cryptocfg command to confirm the configuration.
Severity
ERROR
CVLC-1021
Message
<timestamp>, [CVLC-1021], <sequence-number>,, INFO, <system-name>, User provided
key ID <Key ID from metadata> is ignored while metadata <Key ID provided by the
user> exists.\nContainer: <Target container name>, Initiator: <Initiator physical
WWN>, LUN ID: <LUN ID>.
Probable Cause
Indicates that the key ID provided is ignored because metadata exists on the LUN.
Recommended
Action
No action is required.
Severity
INFO