Auth-1043, Auth-1044, Auth-1045 – Dell POWEREDGE M1000E User Manual

Page 127

Advertising
background image

Fabric OS Message Reference

51

53-1001767-01

AUTH-1043

4

If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.

Severity

ERROR

AUTH-1043

Message

<timestamp>, [AUTH-1043], <sequence-number>,, ERROR, <system-name>, Failed to

enforce device authentication mode:<Device Auth Policy>(error: <Reason Code>).

Probable Cause

Indicates that the Kernel mode setting for F_Port authentication failed. Device authentication will
be defaulted to OFF, and switch will not participate in Diffie Hellman - challenge handshake
authentication protocol (DH-CHAP) authentication with devices.

Recommended

Action

Try setting the device authentication policy manually using the authUtil command.

Severity

ERROR

AUTH-1044

Message

<timestamp>, [AUTH-1044], <sequence-number>,, ERROR, <system-name>,

Authentication <Reason for disabling the port>. Disabling port <port number>.

Probable Cause

Indicates authentication has timed out after multiple retries. The specified port has been disabled
as a result. This problem may be transient due to the system’s central processing unit (CPU) load.
In addition, a defective small form-factor pluggable (SFP) or faulty cable may have caused the
failure.

Recommended

Action

Check the SFP and the cable. Then try to enable the port using the portEnable command.

Severity

ERROR

AUTH-1045

Message

<timestamp>, [AUTH-1045], <sequence-number>,, ERROR, <system-name>, Certificate

not present in this switch in <authentication phase> port <port number>.

Probable Cause

Indicates that the public key infrastructure (PKI) certificate is not installed in this switch.

Recommended

Action

Check the certificate availability using the pkiShow command. Install the certificate and reinitialize
authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.

If the message persists, run supportFtp command (as needed) to set up automatic FTP transfers;
then run the supportSave command and contact your switch service provider.

Severity

ERROR

Advertising