Fw-1435, Fw-1436, Fw-1437 – Dell POWEREDGE M1000E User Manual

Page 420

Advertising
background image

344

Fabric OS Message Reference

53-1001767-01

FW-1435

42

Recommended

Action

Replace the faulty blade.

Severity

WARNING

FW-1435

Message

<timestamp>, [FW-1435], <sequence-number>,, WARNING, <system-name>, Switch status

change contributing factor Flash: usage out of range.

Probable Cause

Indicates that the switch status is not in a healthy state. This occurred because the flash usage is
out of range. The policy was set using the switchStatusPolicySet command.

Recommended

Action

Run the supportSave command to clear out the kernel flash. Refer to the Fabric OS Command
Reference
for more information about this command.

Severity

WARNING

FW-1436

Message

<timestamp>, [FW-1436], <sequence-number>,, WARNING, <system-name>, Switch status

change contributing factor Marginal ports: <Num of marginal ports and the port

numbers> marginal ports. (Ports <Unknown>)

Probable Cause

Indicates that the switch status is not in a healthy state. This occurred because the number of
marginal ports is greater than or equal to the policy set using the switchStatusPolicySet command.
A port is faulty when the port value for Link Loss, Synchronization Loss, Signal Loss, Invalid word,
Protocol error, cyclic redundancy check (CRC) error, Port state change or Buffer Limited Port is
above the high boundary.

Recommended

Action

Replace any faulty or deteriorating small form-factor pluggables (SFPs).

Severity

WARNING

FW-1437

Message

<timestamp>, [FW-1437], <sequence-number>,, WARNING, <system-name>, Switch status

change contributing factor faulty ports: <Num of faulty ports>. (Ports <unknown>.

Probable Cause

Indicates that the switch status is not in a healthy state. This occurred because the number of
faulty ports is greater than or equal to the policy set by the switchStatusPolicySet command. A port
is considered faulty due to hardware failure such as a faulty small form-factor pluggable (SFP) or
port.

Recommended

Action

Replace any faulty or deteriorating small form-factor pluggables (SFPs).

Severity

WARNING