572

Fabric OS Message Reference

53-1001767-01

SPC-2001

93

SPC-2001

Message

<timestamp>, [SPC-2001], <sequence-number>,, ERROR, <system-name>, <slot number

containing Encryption Engine>, <module name>: Crypto error asserted by Vader/OB1

0x%x.

Probable Cause

Indicates the Crypto error is asserted by FPGA.

Recommended

Action

No action is required.

Severity

ERROR

SPC-2002

Message

<timestamp>, [SPC-2002], <sequence-number>,, CRITICAL, <system-name>, <slot

number containing Encryption Engine>, <module name>: Tamper Event: Crypto

subsystem cover tampered.

Probable Cause

Indicates the Crypto subsystem cover is tampered.

Recommended

Action

EE is zeroized. User needs to run initEE and regEE.

Severity

CRITICAL

SPC-2003

Message

<timestamp>, [SPC-2003], <sequence-number>,, INFO, <system-name>, <slot number

containing Encryption Engine>, <module name>: Data Disable status: 0x%x.

Probable Cause

Indicates the Data disable signal status.

Recommended

Action

No action is required.

Severity

INFO

SPC-2004

Message

<timestamp>, [SPC-2004], <sequence-number>,, ERROR, <system-name>, <slot number

containing Encryption Engine>, <module name>: FPGA firmware download failed: 0x%x.

Probable Cause

Indicates the FPGA download has failed.

Recommended

Action

No action is required.

Severity

ERROR