Ssmd-1206, Ssmd-1207, Ssmd-1208 – Dell POWEREDGE M1000E User Manual
Page 676: Ssmd-1209
600
Fabric OS Message Reference
53-1001767-01
SSMD-1206
96
Severity
WARNING
SSMD-1206
Message
<timestamp>, [SSMD-1206], <sequence-number>,, WARNING, <system-name>,CEE failed
programming CoS to PGID policy for CEE Map <CEE Map name>.
Probable Cause
Indicates the DCE System Services Manager (SSM) encountered an unexpected error in
programming the dataplane ASIC for enforcing the CEE Map CoS to PGID mapping feature.
Recommended
Action
Delete and reapply the CEE Map CoS to PGID policy. Restart or power cycle the switch.
Severity
WARNING
SSMD-1207
Message
<timestamp>, [SSMD-1207], <sequence-number>,, WARNING, <system-name>,QoS failed
programming interface 0x <Interface ID> x Default CoS.
Probable Cause
Indicates the DCE System Services Manager (SSM) encountered an unexpected error in
programming the dataplane ASIC for enforcing the interface Default CoS feature.
Recommended
Action
Delete and reapply the QoS interface Default CoS policy. Restart or power cycle the switch.
Severity
WARNING
SSMD-1208
Message
<timestamp>, [SSMD-1208], <sequence-number>,, WARNING, <system-name>,QoS failed
programming interface 0x <Interface ID> x Trust.
Probable Cause
Indicates the DCE System Services Manager (SSM) encountered an unexpected error in
programming the dataplane ASIC for enforcing the interface Trust feature.
Recommended
Action
Delete and reapply the QoS interface Trust policy. Restart or power cycle the switch.
Severity
WARNING
SSMD-1209
Message
<timestamp>, [SSMD-1209], <sequence-number>,, WARNING, <system-name>,QoS failed
programming interface 0x <Interface ID> x CoS Mutation map.
Probable Cause
Indicates the DCE System Services Manager (SSM) encountered an unexpected error in
programming the dataplane ASIC for enforcing the iCoS Mutation mapping feature.