Em-1070, Em-2003 – Dell POWEREDGE M1000E User Manual
Page 242
166
Fabric OS Message Reference
53-1001767-01
EM-1070
22
EM-1070
Message
<timestamp>, [EM-1070], <sequence-number>,, INFO, <system-name>, Slot <FRU slot
number> is being powered on.
Probable Cause
Indicates a blade is being intentionally powered on.
Recommended
Action
No action is required.
Severity
INFO
EM-2003
Message
<timestamp>, [EM-2003], <sequence-number>,, ERROR, <system-name>, <Slot Id or
Switch for pizza boxes> has failed the POST tests. FRU is being faulted.
Probable Cause
Indicates that a field-replaceable unit (FRU) has failed the Power-On Self-Test. Refer to the
/tmp/post[1/2].slot#.log file for more information on faults. To view this log file you must be logged
in at the root level. The ID will be Switch for non-bladed systems.
Recommended
Action
On bladed systems, try reseating the specified FRU.
On nonbladed switches, reboot or power cycle the switch.
If the problem persists:
•
Run the systemverification command to verify that the switch does not have hardware
problems. To run this command root access is required. Refer to theFabric OS Reference
Manual for more information on this command.
•
On bladed systems, replace the specified FRU; otherwise replace the switch.
Severity
ERROR