Em-1070, Em-2003 – Dell POWEREDGE M1000E User Manual

Page 242

Advertising
background image

166

Fabric OS Message Reference

53-1001767-01

EM-1070

22

EM-1070

Message

<timestamp>, [EM-1070], <sequence-number>,, INFO, <system-name>, Slot <FRU slot

number> is being powered on.

Probable Cause

Indicates a blade is being intentionally powered on.

Recommended

Action

No action is required.

Severity

INFO

EM-2003

Message

<timestamp>, [EM-2003], <sequence-number>,, ERROR, <system-name>, <Slot Id or

Switch for pizza boxes> has failed the POST tests. FRU is being faulted.

Probable Cause

Indicates that a field-replaceable unit (FRU) has failed the Power-On Self-Test. Refer to the
/tmp/post[1/2].slot#.log file for more information on faults. To view this log file you must be logged
in at the root level. The ID will be Switch for non-bladed systems.

Recommended

Action

On bladed systems, try reseating the specified FRU.

On nonbladed switches, reboot or power cycle the switch.

If the problem persists:

Run the systemverification command to verify that the switch does not have hardware
problems. To run this command root access is required. Refer to theFabric OS Reference
Manual
for more information on this command.

On bladed systems, replace the specified FRU; otherwise replace the switch.

Severity

ERROR