Cer system messages, Chapter 14, Cer-1001 – Dell POWEREDGE M1000E User Manual

Page 169

Advertising
background image

Fabric OS Message Reference

93

53-1001767-01

Chapter

14

CER System Messages

CER-1001

Message

<timestamp>, [CER-1001], <sequence-number>,, ERROR, <system-name>, HA Sync

broken, since standby Advanced Performance Tuning module does not support FICON

Management Server (FMS).

Probable Cause

Indicates that the high-availability (HA) synchronization between the active and standby control
processors (CPs) is broken, because there is downlevel firmware loaded on the standby CP. The
standby CP does not support the Advanced Performance Tuning module when the fibre
connectivity (FICON) Management Server is enabled.

Recommended

Action

Run the firmwareDownload command to upgrade the firmware on the standby CP.

You can also disable FMS on the active CP.

Severity

ERROR

Advertising