Kac-1008, Kac-1009 – Dell POWEREDGE M1000E User Manual

Page 488

Advertising
background image

412

Fabric OS Message Reference

53-1001767-01

KAC-1008

57

Probable Cause

Indicates that the key archival client is unable to put to the primary or backup key vault.

Recommended

Action

Determine whether the configured key value is operational, and if it is not, change the switch key
vault settings or resolve the operational problem at the vault.

Severity

ERROR

KAC-1008

Message

<timestamp>, [KAC-1008], <sequence-number>,, ERROR, <system-name>, Putting TEP

failed check if there is already an unapproved TEP then delete it, RC=<Error code

from lkm>.

Probable Cause

Indicates that there was already a pending unapproved TEP at the LKM.

Recommended

Action

Log in to the LKM and delete the unapproved TEP.

Severity

ERROR

KAC-1009

Message

<timestamp>, [KAC-1009], <sequence-number>,, ERROR, <system-name>,

Primary(<Primary Keyvault IP Address>) and secondary(<Secondary Keyvault IP

Address>) keyvaults are not in sync. Detected key mismatch with KeyID = <KeyID>.

Probable Cause

Indicates that primary and secondary contents are not synchronized.

Recommended

Action

Synchronize the contents of the primary and secondary using instructions provided by the provider.

Severity

ERROR