Kac-1008, Kac-1009 – Dell POWEREDGE M1000E User Manual
Page 488
412
Fabric OS Message Reference
53-1001767-01
KAC-1008
57
Probable Cause
Indicates that the key archival client is unable to put to the primary or backup key vault.
Recommended
Action
Determine whether the configured key value is operational, and if it is not, change the switch key
vault settings or resolve the operational problem at the vault.
Severity
ERROR
KAC-1008
Message
<timestamp>, [KAC-1008], <sequence-number>,, ERROR, <system-name>, Putting TEP
failed check if there is already an unapproved TEP then delete it, RC=<Error code
from lkm>.
Probable Cause
Indicates that there was already a pending unapproved TEP at the LKM.
Recommended
Action
Log in to the LKM and delete the unapproved TEP.
Severity
ERROR
KAC-1009
Message
<timestamp>, [KAC-1009], <sequence-number>,, ERROR, <system-name>,
Primary(<Primary Keyvault IP Address>) and secondary(<Secondary Keyvault IP
Address>) keyvaults are not in sync. Detected key mismatch with KeyID = <KeyID>.
Probable Cause
Indicates that primary and secondary contents are not synchronized.
Recommended
Action
Synchronize the contents of the primary and secondary using instructions provided by the provider.
Severity
ERROR