Ccfg-1005, Ccfg-1006, Ccfg-1007 – Dell POWEREDGE M1000E User Manual

Page 166: Ccfg-1008

Advertising
background image

90

Fabric OS Message Reference

53-1001767-01

CCFG-1005

13

Probable Cause

Indicates that the startup configuration has been moved or deleted, hence replaying the system
configuration has failed.

Recommended

Action

Use the copy file startup-config command to restore the startup configuration from any backup
retrieved on the server.

Severity

ERROR

CCFG-1005

Message

<timestamp>, [CCFG-1005], <sequence-number>,, INFO, <system-name>, Startup

configuration is updated.

Probable Cause

Indicates that the startup configuration has been updated by the user.

Recommended

Action

No action is required.

Severity

INFO

CCFG-1006

Message

<timestamp>, [CCFG-1006], <sequence-number>,, INFO, <system-name>, Current system

running configuration is updated.

Probable Cause

Indicates that the current running configuration has been updated.

Recommended

Action

No action is required.

Severity

INFO

CCFG-1007

Message

<timestamp>, [CCFG-1007], <sequence-number>,, INFO, <system-name>, startup

configuration is erased.

Probable Cause

Indicates that the startup configuration has been moved or deleted.

Recommended

Action

No action is required.

Severity

INFO

CCFG-1008

Message

<timestamp>, [CCFG-1008], <sequence-number>,, ERROR, <system-name>, CMSH init

failed: <message>.

Advertising