Fabric OS Message Reference

267

53-1001767-01

FICU-1007

36

Recommended

Action

Check if the FICON channel corresponding to the PID in the message is functioning correctly.

Severity

WARNING

FICU-1007

Message

<timestamp>, [FICU-1007], <sequence-number>,, WARNING, <system-name>, <function

name>: Failed to allocate memory while performing <message>.

Probable Cause

Indicates that memory resources are low. This might be a transient problem.

Recommended

Action

If the message persists, check the memory usage on the switch, using the memShow command.

If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.

Severity

WARNING

FICU-1008

Message

<timestamp>, [FICU-1008], <sequence-number>,, WARNING, <system-name>, FMS mode

has been enabled. Ports:<port numbers> have been disabled due to port address

conflict.

Probable Cause

Indicates that the specified ports were disabled when Fibre Connectivity (FICON) Management
Server mode (fmsMode) was enabled. This is due to a port address conflict or the port address
being reserved for the CUP management port.

Recommended

Action

No action is required.

Severity

WARNING

FICU-1009

Message

<timestamp>, [FICU-1009], <sequence-number>,, WARNING, <system-name>, FMS Mode

enable failed due to insufficient frame filtering resources on some ports.

Probable Cause

Indicates that the frame filtering resources required to enable Fibre Connectivity (FICON)
Management Server mode (fmsMode) were not available on some of the ports.

Recommended

Action

Use the perfDelFilterMonitor command to delete the filter-based performance monitors used on all
ports to free up the resources.

Severity

WARNING

Advertising