Bm-1053, Bm-1054, Bm-1055 – Dell POWEREDGE M1000E User Manual

Page 156: Bm-1056

Advertising
background image

80

Fabric OS Message Reference

53-1001767-01

BM-1053

10

Severity

INFO

BM-1053

Message

<timestamp>, [BM-1053], <sequence-number>,, WARNING, <system-name>, Failed to

establish connection between CP and Application Processor. Faulting switch.

Probable Cause

Indicates the control processor (CP) could not establish a connection with the application
processor to communicate.

Recommended

Action

On the Brocade 7500 or 7600, switch off and switch on all the primary power to power-cycle the
unit.

Severity

WARNING

BM-1054

Message

<timestamp>, [BM-1054], <sequence-number>,, INFO, <system-name>, AP firmware

<Blade firmware> is not consistent with system firmware <System firmware>.

Auto-leveling AP firmware to match system firmware.

Probable Cause

Indicates the policy of the specified blade is set to auto-level the blade firmware to the system
firmware. This may be due to one of the following reasons:

Blade firmware was detected to be different from control processor (CP) firmware due to a
firmware upgrade.

The blade was just inserted and had a different version of the firmware loaded.

Recommended

Action

No action is required. The blade will automatically download the updated firmware.

Severity

INFO

BM-1055

Message

<timestamp>, [BM-1055], <sequence-number>,, WARNING, <system-name>,

Firmwaredownload timed-out for AP. Faulting switch.

Probable Cause

Indicates the firmwareDownload command on the application processor (AP) blade has failed.

Recommended

Action

Use the slotPowerOff and slotPowerOn commands or reseat the affected blade. On the Brocade
DCX, 7500 or 7600, switch off and switch on all primary power in order to power-cycle the unit.

Severity

WARNING

BM-1056

Message

<timestamp>, [BM-1056], <sequence-number>,, INFO, <system-name>, AP is not

configured. Persistently disabling all ports on the switch.