Fabric OS Message Reference

37

53-1001767-01

Chapter

3

AN System Messages

AN-1001

Message

<timestamp>, [AN-1001], <sequence-number>,, ERROR, <system-name>, Failed to

allocate memory: <function name>

Probable Cause

Indicates that the specified function has failed to allocate memory.

Recommended

Action

Check memory usage on the switch using the memShow command. Restart or power cycle the
switch.

Severity

ERROR

AN-1002

Message

<timestamp>, [AN-1002], <sequence-number>,, ERROR, <system-name>, Failed to

initialize; rc = <error>

Probable Cause

Indicates that the initialization of the 'trafd' daemon has failed.

Recommended

Action

Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Command Reference Manual
for more information on this command.

Severity

ERROR

AN-1003

Message

<timestamp>, [AN-1003], <sequence-number>,, WARNING, <system-name>, Latency

bottleneck at slot <slot number>, port <port number within slot number>.

<percentage of seconds affected by latency bottlenecking>.2f percent of last

<observation period over which the percentage of affected seconds is reported>

seconds were affected. Avg. inter-frame time <observed frame rate>.4f us.

Probable Cause

For an F_Port, it indicates that the attached device is slow in responding to frames going out of this
port. This latency may be inherent in the device or due to heavy workload on the device. For an
E_Port, it indicates a downstream primary bottleneck.

Recommended

Action

Find the Top Talkers in the egress direction from this port and apply Ingress Rate Limiting to one or
more of them.

Severity

WARNING

Advertising