364

Fabric OS Message Reference

53-1001767-01

HAM-1010

43

HAM-1010

Message

<timestamp>, [HAM-1010], <sequence-number>, SLOT cp-slot-number | CHASSIS,

CRITICAL, <system-name>,Please maunually trigger hareboot/reboot for recovery

from OOM when appropriate.

Probable Cause

Indicates OOM is detected when system is not ready for warm recovery.

Recommended

Action

Manually trigger reboot for cold recovery if needed, or wait until system is ready and use
hareboot/hafailover to trigger warm recovery.

Severity

CRITICAL

HAM-1011

Message

<timestamp>, [HAM-1011], <sequence-number>, SLOT cp-slot-number | CHASSIS,

CRITICAL, <system-name>,Hareboot is automatically triggered for warm recovery

from OOM.

Probable Cause

Indicates OOM is detected when system is ready for warm recovery. Hareboot is automatically
triggered.

Recommended

Action

No action is required.

Severity

CRITICAL

HAM-1012

Message

<timestamp>, [HAM-1012], <sequence-number>, SLOT cp-slot-number | CHASSIS,

CRITICAL, <system-name>,Password database conversion failed.

Probable Cause

Indicates the password database conversion failed.

Recommended

Action

No action is required.

Severity

CRITICAL

HAM-1013

Message

<timestamp>, [HAM-1013], <sequence-number>, SLOT cp-slot-number | CHASSIS,

CRITICAL, <system-name>.

Probable Cause

Indicates a software watchdog detected termination of a restartable daemon, but could not restart
it.

Recommended

Action

If needed manually initiate a reboot/failover.