Fabric OS Message Reference
53-1001767-01
HAM-1010
43
HAM-1010
Message
<timestamp>, [HAM-1010], <sequence-number>, SLOT cp-slot-number | CHASSIS,
CRITICAL, <system-name>,Please maunually trigger hareboot/reboot for recovery
from OOM when appropriate.
Probable Cause
Indicates OOM is detected when system is not ready for warm recovery.
Recommended
Action
Manually trigger reboot for cold recovery if needed, or wait until system is ready and use
hareboot/hafailover to trigger warm recovery.
Severity
CRITICAL
HAM-1011
Message
<timestamp>, [HAM-1011], <sequence-number>, SLOT cp-slot-number | CHASSIS,
CRITICAL, <system-name>,Hareboot is automatically triggered for warm recovery
from OOM.
Probable Cause
Indicates OOM is detected when system is ready for warm recovery. Hareboot is automatically
triggered.
Recommended
Action
No action is required.
Severity
CRITICAL
HAM-1012
Message
<timestamp>, [HAM-1012], <sequence-number>, SLOT cp-slot-number | CHASSIS,
CRITICAL, <system-name>,Password database conversion failed.
Probable Cause
Indicates the password database conversion failed.
Recommended
Action
No action is required.
Severity
CRITICAL
HAM-1013
Message
<timestamp>, [HAM-1013], <sequence-number>, SLOT cp-slot-number | CHASSIS,
CRITICAL, <system-name>.
Probable Cause
Indicates a software watchdog detected termination of a restartable daemon, but could not restart
it.
Recommended
Action
If needed manually initiate a reboot/failover.