CVLM-1005

20

Probable Cause

Indicates that EE nodes in the cluster encryption group have different configurations.

Recommended

Action

Synchronize the configuration in the cluster group using the cryptocfg --commit command. Refer to
the Fabric OS Command Reference Manual for more information on this command.

Severity

WARNING

CVLM-1005

Message

<timestamp>, [CVLM-1005], <sequence-number>,, INFO, <system-name>, Crypto service

is <status> on the switch.

Probable Cause

Indicates that Crypto service is enabled or disabled on the switch.

Recommended

Action

No action is required.

Severity

INFO

CVLM-1006

Message

<timestamp>, [CVLM-1006], <sequence-number>,, WARNING, <system-name>, Crypto

device <device WWN> in target container <container name> is not in AD0.

Probable Cause

Indicates that the crypto device in the crypto target container is not in AD0.

Recommended

Action

Use the ad command to move the crypto device into AD0. Refer to the Fabric OS Command
Reference Manual
for more information on this command.

Severity

WARNING

CVLM-1007

Message

<timestamp>, [CVLM-1007], <sequence-number>,, WARNING, <system-name>, Redirect

zone update failure. Status is <status>.

Probable Cause

Indicates that the redirect zone update has failed.

Recommended

Action

Issue the cryptocfg --commit command again. Refer to the Fabric OS Command Reference Manual
for more information on this command.

Severity

WARNING

CVLM-1008

Message

<timestamp>, [CVLM-1008], <sequence-number>,, WARNING, <system-name>, The member

<EE node WWN><EE slot num> of HAC <HAC name> is not in the fabric.

Probable Cause

Indicates that the member of HAC is not in the fabric.

Advertising