624

Fabric OS Message Reference

53-1001767-01

SWCH-1004

98

SWCH-1004

Message

<timestamp>, [SWCH-1004], <sequence-number>,, ERROR, <system-name>, Blade attach

failed during recovery, disabling slot = <slot number>

.

Probable Cause

Indicates a blade has failed during failover or recovery.

Recommended

Action

On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn
command.

On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000,
7500, or AP7600 switch, reboot or power cycle the switch

Severity

ERROR

SWCH-1005

Message

<timestamp>, [SWCH-1005], <sequence-number>,, ERROR, <system-name>, Diag attach

failed during recovery, disabling slot = <slot number>

.

Probable Cause

Indicates the Diag blade attach has failed during failover or recovery.

Recommended

Action

On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn
command.

On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000,
7500, or AP7600 switch, reboot or power cycle the switch.

Severity

ERROR

SWCH-1006

Message

<timestamp>, [SWCH-1006], <sequence-number>,, WARNING, <system-name>, HA state

out of sync: Standby CP (ver = <standby SWC version>) does not support NPIV

functionality. (active ver = <active SWC version>, NPIV devices = <'1' if NPIV

devices exist; Otherwise '0'. >).

Probable Cause

Indicates the standby control processor (CP) does not support N_Port ID Virtualization (NPIV)
functionality, but the switch has some NPIV devices logged into the fabric.

Recommended

Action

Load a firmware version on standby that supports NPIV functionality, using the firmwareDownload
command.

Severity

WARNING

SWCH-1007

Message

<timestamp>, [SWCH-1007], <sequence-number>,, WARNING, <system-name>, Switch port

<port number> disabled due to \"<disable reason>\".

Probable Cause

Indicates the switch port is disabled due to the reason displayed in the message.