Fabric OS Message Reference
53-1001767-01
L2SS-1005
60
Recommended
Action
Restart the l2sysd daemon.
Severity
ERROR
L2SS-1005
Message
<timestamp>, [L2SS-1005], <sequence-number>,, ERROR, <system-name>,
Mac-address-table hash failed even after two attempts for slot <slot> chip <chip>.
Probable Cause
Indicates a mac-address-table hash failure happened even after two hash changes on the chip.
Recommended
Action
Restart the l2sysd daemon.
Severity
ERROR
L2SS-1006
Message
<timestamp>, [L2SS-1006], <sequence-number>,, INFO, <system-name>,
Mac-address-table table on slot <slot_id> chip <chip_id> is 95 percent full.
Probable Cause
Indicates that the mac-address-table on the chip is 95% full.
Recommended
Action
Clear some of the entries, or wait till old entries age out.
Severity
INFO
L2SS-1007
Message
<timestamp>, [L2SS-1007], <sequence-number>,, INFO, <system-name>,
MMac-address-table on slot <slot_id> chip <chip_id> is less than 90 percent full.
Probable Cause
Indicates that the mac-address-table is less than 90% full.
Recommended
Action
No action is required. L2SYS will start learning the entries.
Severity
INFO