Fabric OS Message Reference

641

53-1001767-01

Chapter

104

TS System Messages

TS-1001

Message

<timestamp>, [TS-1001], <sequence-number>,, WARNING, <system-name>, NTP Query

failed: <error code>.

Probable Cause

Indicates a network time protocol (NTP) query to the configured external clock server failed. Local
clock time on the principal or primary fabric configuration server (FCS) switch is used for fabric
synchronization.

This might be logged during temporary operational issues such as IP network connection issues to
the external clock server. If it does not recur, it can be ignored.

Recommended

Action

Verify the configured external clock server is available and functional. If that external clock server is
not available, choose another.

Severity

WARNING

TS-1002

Message

<timestamp>, [TS-1002], <sequence-number>,, INFO, <system-name>, < Type of clock

server used > Clock Server used instead of < Type of clock server configured >:

locl: 0x<code> remote: 0x<code>.

Probable Cause

Indicates the fabric time synchronization distributed from the principal or primary fabric
configuration server (FCS) switch was not sourced from the Type of clock server configured,
instead, an alternate server was used, indicated by Type of clock server used. The type of clock
server used or configured might be either one of the following:

LOCL
Local clock on the principal or primary FCS switch

External
External NTP server address configured

This might be logged during temporary operational issues such as IP network connection issues to
the external clock server or if the fabric is configured for external time synchronization but the
principal or primary FCS does not support the feature. If the message does not recur, it should be
ignored.

Recommended

Action

Run the tsClockServer command to verify that the principal or primary FCS switch has the clock
server IP configured correctly. Verify this clock server is accessible to the switch and functional. If
the principal or primary FCS does not support the feature, either choose a different switch for the
role or reset the clock server to LOCL.

Severity

INFO