Fabric OS Message Reference
381
53-1001767-01
HIL-1601
45
HIL-1601
Message
<timestamp>, [HIL-1601], <sequence-number>,, ERROR, <system-name>, Using backup
temperature sensor. Attention needed.
Probable Cause
Indicates that temperature readings from the primary sensor are out of range.
Recommended
Action
Run the fanShow command to verify that all fans are operating correctly. Replace any deteriorating
fan field-replaceable units (FRUs).
Run the tempShow command to verify temperature values. If any sensor is too high, monitor the
switch. Try rebooting or power cycling the switch.
Severity
ERROR
HIL-1602
Message
<timestamp>, [HIL-1602], <sequence-number>, FFDC, CRITICAL, <system-name>,
Multiple temperature sensors failed. Service immediately.
Probable Cause
Indicates that temperature readings from multiple sensors are out of range.
Recommended
Action
Run the fanShow command to verify that all fans are operating correctly. Replace any deteriorating
fan field-replaceable units (FRUs).
Run the tempShow command to verify temperature values. If any sensor is too high, monitor the
switch. Try rebooting or power cycling the switch.
Severity
CRITICAL
HIL-1603
Message
<timestamp>, [HIL-1603], <sequence-number>, FFDC, CRITICAL, <system-name>,
<failure count> fans out of service. System is shutting down immediately.
Probable Cause
Indicates that the total fan failure count is greater than or equal to two.
Recommended
Action
To avoid causing damage to the switch, the system shuts down automatically. To help prevent
future problems, make sure that all the fans are working properly.
Severity
CRITICAL
HIL-1605
Message
<timestamp>, [HIL-1605], <sequence-number>, FFDC, INFO, <system-name>, High
temperature (<measured temperature> C), fan speed increasing per environmental
specifications.
Probable Cause
Indicates that temperatures in the system have risen above the threshold and that the fan speed is
being increased.