Em-1048, Em-1049, Em-1050 – Dell POWEREDGE M1000E User Manual

Page 237

Advertising
background image

Fabric OS Message Reference

161

53-1001767-01

EM-1048

22

Probable Cause

Indicates that the control processor (CP) is no longer faulted. This message usually follows
EM-1033. The new standby CP is in the process of rebooting and has turned off the CP_ERR signal.

Recommended

Action

No action is required.

Severity

INFO

EM-1048

Message

<timestamp>, [EM-1048], <sequence-number>,, INFO, <system-name>, <FRU Id> I2C

access recovered: state <current state>

Probable Cause

Indicates that the I2C bus problems have been resolved and I2C access to the field-replaceable
unit (FRU) has become available again.

Recommended

Action

The EM-1029 error can be a transitory error; if the problem resolves, the EM-1048 message is
displayed.

Severity

INFO

EM-1049

Message

<timestamp>, [EM-1049], <sequence-number>,, INFO, <system-name>, FRU

<FRU Id>

insertion detected.

Probable Cause

Indicates that a field-replaceable unit (FRU) of the type and location specified by the FRU ID was
detected as having been inserted into the chassis.

Recommended

Action

No action is required.

Severity

INFO

EM-1050

Message

<timestamp>, [EM-1050], <sequence-number>,, INFO, <system-name>, FRU

<FRU Id>

removal detected.

Probable Cause

Indicates that a field-replaceable unit (FRU) of the specified type and location was removed from
the chassis.

Recommended

Action

Verify that the FRU was intended to be removed. Replace the FRU as soon as possible.

Severity

INFO

Advertising