Sulb-1020, Sulb-1021, Sulb-1023 – Dell POWEREDGE M1000E User Manual

Page 823

Advertising
background image

Fabric OS Message Reference

747

53-1001767-01

SULB-1020

128

Recommended

Action

Run the slotShow command. If the blade is in a FAULTY state, run the slotPowerOff and
slotPowerOn commands to trigger another firmwareDownload. If the blade is stuck in LOADING
state, remove and re-insert the blade to trigger another firmwareDownload. If the problem persists,
contact your switch service provider.

Severity

ERROR

SULB-1020

Message

AUDIT, <timestamp>, [SULB-1020], ERROR, FIRMWARE, <event-initiator-details>,

<event-location>, , New firmware failed to boot in slot

<Slot number>

.

Probable Cause

Indicates the BP blade should restart with the new image, but is still running the old image. This
error may indicate that the new image has not been loaded correctly to the specified blade.

Recommended

Action

Run the slotShow command. If the blade is in a FAULTY state, run the slotPowerOff and
slotPowerOn commands to trigger another firmwareDownload to the blade. If the blade is stuck in
LOADING state, remove and re-insert the blade to trigger another firmwareDownload. If the problem
persists, contact your switch service provider.

Severity

ERROR

SULB-1021

Message

AUDIT, <timestamp>, [SULB-1021], WARNING, FIRMWARE, <event-initiator-details>,

<event-location>, , Firmware is being downloaded to the blade in slot

<Slot

number>.

Probable Cause

Indicates the firmware is being loaded to the specified blade.

Recommended

Action

Run the firmwareDownloadStatus command to monitor the firmwareDownload progress. After it
finishes, run the firmwareShow command to verify the firmware versions.

Severity

WARNING

SULB-1023

Message

AUDIT, <timestamp>, [SULB-1023], WARNING, FIRMWARE, <event-initiator-details>,

<event-location>, , The blade in slot

<Slot number>

has rebooted during

firmwaredownload.

Probable Cause

Indicates there may be an error caused by an unexpected disruption of the firmwareDownload
command, for example, by powering off and on of the indicated BP blade in the middle of a
firmwareDownload. The error may also be caused by persistent storage hardware failure or by a
software error.

Advertising