Sulb-1035, Sulb-1037, Sulb-1038 – Dell POWEREDGE M1000E User Manual

Page 826

Advertising
background image

750

Fabric OS Message Reference

53-1001767-01

SULB-1035

128

Recommended

Action

Reboot the switch. This will cause the internal image to be relocated again. Use the
firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your
switch service provider.

Severity

ERROR

SULB-1035

Message

AUDIT, <timestamp>, [SULB-1035], ERROR, FIRMWARE, <event-initiator-details>,

<event-location>, , An error has occurred during relocation of the internal image.

Probable Cause

Indicates an error has occurred during the relocation of the internal image. The error may be
caused by inconsistent internal firmware image. It may also be caused by the internal Ethernet or
persistent storage hardware failure.

Recommended

Action

Reset the switch. This will cause the internal image to be relocated again. If the problem persists,
contact your switch service provider.

Severity

ERROR

SULB-1037

Message

AUDIT, <timestamp>, [SULB-1037], ERROR, FIRMWARE, HCL failed. Reboot the switch

manually using the reboot command. However, it will disrupt the FC traffic.

Probable Cause

Indicates HCL has failed. Many reasons, such as domain not confirmed, can cause this failure.

Recommended

Action

Run the reboot command to restart the switch manually.

Severity

ERROR

SULB-1038

Message

AUDIT, <timestamp>, [SULB-1038], WARNING, FIRMWARE, Co-CPU has not booted up

properly. Skip the firmwaredownload command on the co-CPU.

Probable Cause

Indicates that the Main CPU cannot access the co-CPU to update the firmware on the co-CPU or run
any other firmwaredownload command on the co-CPU. If firmwareDownload in progress it will
continue without updating the co-CPU firmware.

Recommended

Action

After firmwaredownload completes, reboot the CP manually to bring up the co-CPU and run the
firmwareDownload command again. If the problem persists, contact the service provider.

Severity

WARNING

Advertising