SEC-1078

90

Severity

ERROR

SEC-1078

Message

<timestamp>, [SEC-1078], <sequence-number>,, ERROR, <system-name>, No new data to

abort.

Probable Cause

Indicates there are no new changes in the defined security policy database that can be aborted.

Recommended

Action

Verify the security event was planned. Verify if there were really any changes to the defined policy
database that can be aborted.

Severity

ERROR

SEC-1079

Message

<timestamp>, [SEC-1079], <sequence-number>,, ERROR, <system-name>, The policy

name <policy name> is invalid.

Probable Cause

Indicates the policy name entered in the secPolicyCreate|Activate|Add|Delete command was
invalid.

Recommended

Action

Run the command again using a valid policy name.

Severity

ERROR

SEC-1080

Message

<timestamp>, [SEC-1080], <sequence-number>,, ERROR, <system-name>, Operation

denied. Please, use secModeEnable command.

Probable Cause

Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.

Severity

ERROR

SEC-1081

Message

<timestamp>, [SEC-1081], <sequence-number>,, ERROR, <system-name>, Entered a name

for a DCC policy ID that was not unique.