Fw-1124, Fw-1125, Fw-1126 – Dell POWEREDGE M1000E User Manual

Page 375

Advertising
background image

Fabric OS Message Reference

299

53-1001767-01

FW-1124

42

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.

Severity

INFO

FW-1124

Message

<timestamp>, [FW-1124], <sequence-number>,, INFO, <system-name>, <Label>, is

between high and low boundaries(High=<High value>, Low=<Low value>). Current value

is <Value> <Unit>.

Probable Cause

Indicates that the number of domain ID changes has changed from a value outside of the
acceptable range to a value within the acceptable range. Domain ID changes occur when there is a
conflict of domain IDs in a single fabric and the principal switch has to assign another domain ID to
the switch.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.

Severity

INFO

FW-1125

Message

<timestamp>, [FW-1125], <sequence-number>,, INFO, <system-name>, <Label>, value

has changed(High=<High value>, Low=<Low value>). Current value is <Value> <Unit>.

Probable Cause

Indicates that the number of segmentations has changed. Segmentation changes might occur due
to:

Zone conflicts.

Domain conflicts.

Segmentation of the principal link between two switches.

Incompatible link parameters. During E_Port initialization, ports exchange link parameters.
Rarely, incompatible parameters result in segmentation.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.

Severity

INFO

FW-1126

Message

<timestamp>, [FW-1126], <sequence-number>,, INFO, <system-name>, <Label>, is

below low boundary(High=<High value>, Low=<Low value>). Current value is <Value>

<Unit>.

Probable Cause

Indicates that the number of segmentations has fallen below the low boundary. Segmentation
changes might occur due to:

Zone conflicts.

Advertising