HIL-1101

Message

<timestamp>, [HIL-1101], <sequence-number>,, ERROR, <system-name>, Slot <slot

number> faulted, <nominal voltage> (<measured voltage>) is above threshold.

Probable Cause

Indicates that the blade voltage is above threshold.

Recommended

Action

Replace the faulty blade or switch (for nonbladed switches).

Severity

ERROR

HIL-1102

Message

<timestamp>, [HIL-1102], <sequence-number>,, ERROR, <system-name>, Slot <slot

number> faulted, <nominal voltage> (<measured voltage>) is below threshold.

Probable Cause

Indicates that the blade voltage is below threshold.

Recommended

Action

Replace the faulty blade or switch (for nonbladed switches).

Severity

ERROR

HIL-1103

Message

<timestamp>, [HIL-1103], <sequence-number>,, ERROR, <system-name>, Blower <blower

number> faulted, <nominal voltage> (<measured voltage>) is above threshold.

Probable Cause

Indicates that the fan voltage is above threshold.

Recommended

Action

Run the psShow command to verify the power supply status.

Try to reseat the faulty fan field-replaceable units (FRUs) and power supply FRU to verify that they
are seated properly.

If the problem persists, replace the fan FRU or the power supply FRU as necessary.

Severity

ERROR