Fw-1535, Fw-3010, Fw-3011 – Dell POWEREDGE M1000E User Manual

Page 432: Fw-3012

Advertising
background image

356

Fabric OS Message Reference

53-1001767-01

FW-1535

42

FW-1535

Message

<timestamp>, [FW-1535], <sequence-number>,, INFO, <system-name>, Fabric Watch has

stopped portfencing feature for <Area String> loss area in <Port Name> class since

FOS6.3. Disabling port fencing feature for this.

Probable Cause

Indicates that in previous versions portfencing is configured for Link/Sync loss, but after upgrading
to new version, in which portfencing is not suppoted, resets the above bit.

Recommended

Action

No action is required. You are informed that PF bit is reset.

Severity

INFO

FW-3010

Message

<timestamp>, [FW-3010], <sequence-number>,, INFO, <system-name>, <Port

Name>,<Label> value has changed(High=<High value>, Low=<Low value>). Current

value is <Value> <Unit>.

Probable Cause

Indicates that the circuit utilization has changed.

Recommended

Action

Respond to this message as it is appropriate to the particular policy of the end-user installation.

Severity

INFO

FW-3011

Message

<timestamp>, [FW-3011], <sequence-number>,, INFO, <system-name>, <Port

Name>,<Label> is below low boundary(High=<High value>, Low=<Low value>). Current

value is <Value> <Unit>.

Probable Cause

Indicates that the circuit utilization is below threshold.

Recommended

Action

No action is required.

Severity

INFO

FW-3012

Message

<timestamp>, [FW-3012], <sequence-number>,, WARNING, <system-name>, <Port

Name>,<Label> is above high boundary(High=<High value>, Low=<Low value>). Current

value is <Value> <Unit>.

Probable Cause

Indicates that the circuit utilization is above threshold.

Advertising