SEC-1099

90

SEC-1099

Message

<timestamp>, [SEC-1099], <sequence-number>,, ERROR, <system-name>, Please enable

your switch before running secModeEnable.

Probable Cause

Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.

Severity

ERROR

SEC-1100

Message

<timestamp>, [SEC-1100], <sequence-number>,, ERROR, <system-name>, FCS switch

present. Command terminated.

Probable Cause

Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.

Severity

ERROR

SEC-1101

Message

<timestamp>, [SEC-1101], <sequence-number>,, ERROR, <system-name>, Failed to

enable security on all switches. Please retry later.

Probable Cause

Indicates the security enable failed on the fabric because one or more switches in the fabric are
busy.

Recommended

Action

Verify that the security event was planned. If the security event was planned, run the
secFabricShow command to verify that all switches in the fabric are in the ready state. When all
switches are in the ready state, retry the operation.

Severity

ERROR

SEC-1102

Message

<timestamp>, [SEC-1102], <sequence-number>,, ERROR, <system-name>, Fail to

download <security data>.