Fabric OS Message Reference

53-1001767-01

BL-1015

7

Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled.

If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors
are encountered again:

On the Brocade 24000, and 48000, replace the blade field-replaceable unit (FRU).

On the Brocade 3900, replace the motherboard FRU.

On the Brocade 200E, 3016, 3250, 3850, or 4100, 4012, 4016, 4018, 4024, 4900, 7500,
AP7600, and 5000, replace the switch.

Severity

ERROR

BL-1015

Message

<timestamp>, [BL-1015], <sequence-number>,, ERROR, <system-name>, bport <port

number> port is faulted. status=0x<interrupt status>.

Probable Cause

Indicates that the port generated an excessive number of interrupts that might prove fatal to the
switch operation. The port is disabled to prevent the CP from becoming too busy. The bport is the
blade port; this number might not correspond to a user port number.

Recommended

Action

Make sure to capture the console output during this process.

On a bladed switch, run the slotPowerOff and slotPowerOn commands.

On a nonbladed switch, reboot the switch.

Run the systemVerification command to determine if there is a hardware error. To run this
command root access is required.

Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled.

If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors
are encountered again:

On the Brocade 24000, and 48000, replace the blade field-replaceable unit (FRU).

On the Brocade 3900, replace the motherboard FRU.

On the Brocade 200E, 3016, 3250, 3850, or 4100, 4012, 4016, 4018, 4024, 4900, 7500,
AP7600, and 5000, replace the switch.

Severity

ERROR

BL-1016

Message

<timestamp>, [BL-1016], <sequence-number>, FFDC, CRITICAL, <system-name>, Blade

port <port number> in slot <slot number> failed to enable.

Probable Cause

Indicates that the specified blade port has failed to get enabled.

Recommended

Action

Make sure that the blade is seated correctly.

If the blade is seated correctly, restart or power cycle the blade.