Fabric OS Message Reference

637

53-1001767-01

TRCE-1007

102

TRCE-1007

Message

<timestamp>, [TRCE-1007], <sequence-number>,, ERROR, <system-name>, Notification

of this CP has failed. Parameters temporarily out of sync with other CP.

Probable Cause

Indicates that the active CP is unable to alert the standby CP of a change in trace status. This
message is only applicable to the Brocade 24000, and 48000.

Recommended

Action

This message is often transitory. Wait for a few minutes and retry the command.

If the message persists, run the supportFtp command to set up automatic FTP transfers; then run
the supportSave command and contact your switch service provider.

Severity

ERROR

TRCE-1008

Message

<timestamp>, [TRCE-1008], <sequence-number>, FFDC, CRITICAL, <system-name>,

Unable to load trace parameters.

Probable Cause

Indicates that the active CP is unable to read stored trace parameters.

Recommended

Action

Restart the CP (dual-CP system) or restart the switch.

If the message persists, run the supportFtp command to set up automatic FTP transfers; then run
the supportSave command and contact your switch service provider.

Severity

CRITICAL

TRCE-1009

Message

<timestamp>, [TRCE-1009], <sequence-number>,, ERROR, <system-name>, Unable to

alert active CP that a dump has occurred.

Probable Cause

Indicates that the standby CP is unable to communicate trace information to active CP. This
message is only applicable to the Brocade 24000 and 48000.

Recommended

Action

Run the haShow command to verify that the current CP is standby and the active CP is active.

If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.

Severity

ERROR

TRCE-1010

Message

<timestamp>, [TRCE-1010], <sequence-number>,, ERROR, <system-name>, Traced fails

to start