Ssmd-1202, Ssmd-1203, Ssmd-1204 – Dell POWEREDGE M1000E User Manual

Page 675: Ssmd-1205

Advertising
background image

Fabric OS Message Reference

599

53-1001767-01

SSMD-1202

96

SSMD-1202

Message

<timestamp>, [SSMD-1202], <sequence-number>,, WARNING, <system-name>,QoS failed

programming interface 0x<Interface ID> x 802.3x Pause flow control.

Probable Cause

Indicates the DCE System Services Manager (SSM) encountered an unexpected error in
programming the dataplane ASIC for enforcing the interface 802.3x Pause flow control feature.

Recommended

Action

Delete and reapply QoS 802.3x Pause flow control policy. Restart or power cycle the switch.

Severity

WARNING

SSMD-1203

Message

<timestamp>, [SSMD-1203], <sequence-number>,, WARNING, <system-name>,QoS failed

programming interface 0x <Interface ID> x PFC flow control.

Probable Cause

Indicates the DCE System Services Manager (SSM) encountered an unexpected error in
programming the dataplane ASIC for enforcing the interface PFC flow control feature.

Recommended

Action

Delete and reapply QoS 802.3x Pause flow control policy. Restart or power cycle the switch.

Severity

WARNING

SSMD-1204

Message

<timestamp>, [SSMD-1204], <sequence-number>,, WARNING, <system-name>,QoS failed

initializing ASIC <ASIC slot number> / <ASIC chip number>.

Probable Cause

Indicates the DCE System Services Manager (SSM) encountered an unexpected error in initializing
the dataplane ASIC QoS infrastructure.

Recommended

Action

Restart or power cycle the switch.

Severity

WARNING

SSMD-1205

Message

<timestamp>, [SSMD-1205], <sequence-number>,, WARNING, <system-name>,CEE failed

programming ETS policy for CEE Map <CEE Map name>.

Probable Cause

Indicates the DCE System Services Manager (SSM) encountered an unexpected error in
programming the dataplane ASIC for enforcing the CEE Map ETS feature.

Recommended

Action

Delete and reapply the CEE Map ETS policy. Restart or power cycle the switch.

Advertising