192

Fabric OS Message Reference

53-1001767-01

FABS-1012

27

Recommended

Action

Reboot or power-cycle the CP or system.

If the message persists, run the firmwareDownload command to update the firmware.

Severity

ERROR

FABS-1012

Message

<timestamp>, [FABS-1012], <sequence-number>,, ERROR, <system-name>, <Method

name>[<Method tag number>]:FRU state transition failed. Current state 0x<Current

state of FRU> Requested state 0x<Requested new state of FRU> err 0x<Error code>

Probable Cause

A FRU could not be transitioned to the requested state. This is usually an internal Fabric OS
problem.

Recommended

Action

Reboot or power-cycle the CP or system.

If the message persists, run the firmwareDownload command to update the firmware.

Severity

ERROR

FABS-1013

Message

<timestamp>, [FABS-1013], <sequence-number>,, ERROR, <system-name>, <Method

name>[<Method tag number>]:Unknown blade type 0x<Blade type>

Probable Cause

Indicates an unrecognized type of blade has been discovered in the system.

This may be caused by an incorrect FRU header, inability to read the FRU header, or the blade may
not be supported by this platform or Fabric OS version.

Recommended

Action

Verify that the blade is valid for use in this system and this version of Fabric OS.

Try reseating the blade.

If this is a valid blade and reseating does not fix the problem, then replace the blade.

Severity

ERROR

FABS-1014

Message

<timestamp>, [FABS-1014], <sequence-number>,, ERROR, <system-name>, <Method

name>[<Method tag number>]:Unknown FRU type 0x<FRU Object type>

Probable Cause

Indicates an unrecognized type of FRU has been discovered in the system.

This may be caused by an incorrect FRU header, inability to read the FRU header, or the FRU may
not be supported by this platform or Fabric OS version.

Recommended

Action

Verify that the FRU is valid for use in this system and this version of Fabric OS.

Try reseating the FRU.

If this is a valid FRU and reseating does not help, then replace the FRU.