Snmp system messages, Chapter 92, Snmp-1001 – Dell POWEREDGE M1000E User Manual
Page 643: Snmp-1002, Snmp-1003, Chapter
Fabric OS Message Reference
567
53-1001767-01
Chapter
92
SNMP System Messages
SNMP-1001
Message
<timestamp>, [SNMP-1001], <sequence-number>,, ERROR, <system-name>, SNMP service
is not available <Reason>.
Probable Cause
Indicates the simple network management protocol (SNMP) service could not be started because
of the specified Reason. You will not be able to query the switch through SNMP.
Recommended
Action
Verify the IP address for the Ethernet and Fibre Channel interface is set correctly. If the specified
Reason is an initialization failure, the switch has to restart.
Severity
ERROR
SNMP-1002
Message
<timestamp>, [SNMP-1002], <sequence-number>,, ERROR, <system-name>, SNMP <Error
Details> initialization failed.
Probable Cause
Indicates the initialization of the simple network management protocol (SNMP) service has failed
and you will not be able to query the switch through SNMP.
Recommended
Action
Restart or power cycle the switch. This will automatically initialize SNMP.
Severity
ERROR
SNMP-1003
Message
<timestamp>, [SNMP-1003], <sequence-number>,, ERROR, <system-name>, Distribution
of Community Strings to Secure Fabric failed.
Probable Cause
Indicates that the changes in the simple network management protocol (SNMP) community strings
could not be propagated to other switches in the secure fabric.
Recommended
Action
Retry changing the SNMP community strings from the primary switch.
Severity
ERROR