Flod system messages, Chapter 38, Flod-1001 – Dell POWEREDGE M1000E User Manual

Page 351: Flod-1003, Flod-1004, Flod-1005, Chapter

Advertising
background image

Fabric OS Message Reference

275

53-1001767-01

Chapter

38

FLOD System Messages

FLOD-1001

Message

<timestamp>, [FLOD-1001], <sequence-number>, FFDC, WARNING, <system-name>,

Unknown LSR type: port <port number>, type <LSR header type>

Probable Cause

Indicates that the link state record (LSR) type is unknown. The following two LSR header types are
the only known types: 1 - Unicast and 3 - Multicast.

Recommended

Action

No action is required because the record is discarded.

Severity

WARNING

FLOD-1003

Message

<timestamp>, [FLOD-1003], <sequence-number>,, WARNING, <system-name>, Link count

exceeded in received LSR, value = <link count number>

Probable Cause

Indicates that the acceptable link count has exceeded in the received link state record (LSR).

Recommended

Action

No action is required because the record is discarded.

Severity

WARNING

FLOD-1004

Message

<timestamp>, [FLOD-1004], <sequence-number>, FFDC, ERROR, <system-name>,

Excessive LSU length = <LSU length>

Probable Cause

Indicates that the LSU size exceeds what the system can support.

Recommended

Action

Reduce the number of switches in the fabric or reduce the number of redundant ISLs between two
switches.

Severity

ERROR

FLOD-1005

Message

<timestamp>, [FLOD-1005], <sequence-number>,, WARNING, <system-name>, Invalid

received domain ID: <domain number>