Fabric OS Message Reference
129
53-1001767-01
CVLC-1022
19
CVLC-1022
Message
<timestamp>, [CVLC-1022], <sequence-number>,, INFO, <system-name>, User provided
key ID <Key ID from metadata> is ignored while data state is clear
text.\nContainer: <Target container name>, Initiator: <Initiator physical WWN>,
LUN ID: <LUN ID>.
Probable Cause
Indicates that the key ID provided is ignored because the data state is clear text.
Recommended
Action
No action is required.
Severity
INFO
CVLC-1023
Message
<timestamp>, [CVLC-1023], <sequence-number>,, INFO, <system-name>, Rebalance
recommended on EE: <EE name>.
Probable Cause
Indicates that due to container configuration changes, weights are not balanced on OB1s.
Recommended
Action
Run "cryptocfg --rebalance" to increase system performance.
Severity
INFO
CVLC-1024
Message
<timestamp>, [CVLC-1024], <sequence-number>,, INFO, <system-name>, Device
Decommission operation <Decommission state (succeeded/failed)>.\nContainer:
<Target container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Probable Cause
Indicates that the device decommission process has either succeeded or failed.
Recommended
Action
No action is required.
Severity
INFO
CVLC-1025
Message
<timestamp>, [CVLC-1025], <sequence-number>,, ERROR, <system-name>, Secondary
Metadata exists for encrypted LUN not configured with -newLUN option .\nContainer:
<Target container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Probable Cause
Indicates that the secondary metadata exists on the LUN that is not configured with --newLUN
option.
Recommended
Action