Cvlc-1022, Cvlc-1023, Cvlc-1024 – Dell POWEREDGE M1000E User Manual

Page 205: Cvlc-1025

Advertising
background image

Fabric OS Message Reference

129

53-1001767-01

CVLC-1022

19

CVLC-1022

Message

<timestamp>, [CVLC-1022], <sequence-number>,, INFO, <system-name>, User provided

key ID <Key ID from metadata> is ignored while data state is clear

text.\nContainer: <Target container name>, Initiator: <Initiator physical WWN>,

LUN ID: <LUN ID>.

Probable Cause

Indicates that the key ID provided is ignored because the data state is clear text.

Recommended

Action

No action is required.

Severity

INFO

CVLC-1023

Message

<timestamp>, [CVLC-1023], <sequence-number>,, INFO, <system-name>, Rebalance

recommended on EE: <EE name>.

Probable Cause

Indicates that due to container configuration changes, weights are not balanced on OB1s.

Recommended

Action

Run "cryptocfg --rebalance" to increase system performance.

Severity

INFO

CVLC-1024

Message

<timestamp>, [CVLC-1024], <sequence-number>,, INFO, <system-name>, Device

Decommission operation <Decommission state (succeeded/failed)>.\nContainer:

<Target container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.

Probable Cause

Indicates that the device decommission process has either succeeded or failed.

Recommended

Action

No action is required.

Severity

INFO

CVLC-1025

Message

<timestamp>, [CVLC-1025], <sequence-number>,, ERROR, <system-name>, Secondary

Metadata exists for encrypted LUN not configured with -newLUN option .\nContainer:

<Target container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.

Probable Cause

Indicates that the secondary metadata exists on the LUN that is not configured with --newLUN
option.

Recommended

Action

Use th ecryptocfg command to remove and add the LUN with --newLUN option.

Advertising