Icpd system messages, Chapter 52, Icpd-1001 – Dell POWEREDGE M1000E User Manual

Page 473: Icpd-1002, Icpd-1003, Icpd-1004, Chapter

Advertising
background image

Fabric OS Message Reference

397

53-1001767-01

Chapter

52

ICPD System Messages

ICPD-1001

Message

<timestamp>, [ICPD-1001], <sequence-number>,, ERROR, <system-name>, Failed to

allocate memory: (<function name>).

Probable Cause

Indicates that the specified function failed to allocate memory.

Recommended

Action

Check memory usage on the switch using the memShow command.

Reboot or power cycle the switch.

Severity

ERROR

ICPD-1002

Message

<timestamp>, [ICPD-1002], <sequence-number>,, ERROR, <system-name>, Failed to

initialize <module> rc = <error>.

Probable Cause

Indicates that an initialization of a module within the ICPD failed.

Recommended

Action

Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Command Reference
for more information on this command.

Severity

ERROR

ICPD-1003

Message

<timestamp>, [ICPD-1003], <sequence-number>,, INFO, <system-name>, iSCSI

configuration has been committed by switch (<domain id>).

Probable Cause

Indicates the iSCSI configuration has been committed by a remote switch in the fabric.

Recommended

Action

No action is required.

Severity

INFO

ICPD-1004

Message

<timestamp>, [ICPD-1004], <sequence-number>,, WARNING, <system-name>, iSNS Client

service is detected on multiple switches in fabric.

Probable Cause

Indicates the iSNS Client service is enabled on multiple switches in the fabric.

Advertising