Anv system messages, Chapter 5, Anv-1001 – Dell POWEREDGE M1000E User Manual

Page 129: Anv-1002, Anv-1003, Chapter

Advertising
background image

Fabric OS Message Reference

53

53-1001767-01

Chapter

5

ANV System Messages

ANV-1001

Message

<timestamp>, [ANV-1001], <sequence-number>,, ERROR, <system-name>, Port <port

number> port fault. Please change the SFP or check cable.

Probable Cause

Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, or a faulty
cable between peer ports.

Recommended

Action

Verify if you are using compatible SFPs on the peer ports. Verify if the SFPs have deteriorated and if
the Fibre Channel cable is faulty. Replace the SFPs or the cable if necessary.

Severity

ERROR

ANV-1002

Message

<timestamp>, [ANV-1002], <sequence-number>,Ffdc, ERROR, <system-name>, Port <port

number> chip faulted due to internal error.

Probable Cause

Indicates an internal error. All the ports on the blade or switch will be disrupted.

Recommended

Action

For a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade to recover
the system. For a non-bladed system, perform the fastBoot command on the switch to recover the
system.

Severity

ERROR

ANV-1003

Message

<timestamp>, [ANV-1003], <sequence-number>,, CRITICAL, <system-name>, <slot

number>,<chip index>: HW ASIC Chip error. Type = 0x<chip error type>, Error =

<chip error string>..

Probable Cause

Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may
degrade data traffic.

Recommended

Action

Restart the system at the next maintenance window. If the problem persists, replace the blade.

Severity

CRITICAL