Bl-1037, Bl-1038, Bl-1039 – Dell POWEREDGE M1000E User Manual

Page 147: Bl-1041

Advertising
background image

Fabric OS Message Reference

71

53-1001767-01

BL-1037

7

BL-1037

Message

<timestamp>, [BL-1037], <sequence-number>,, CRITICAL, <system-name>, Faulting

chip in slot = <slot number>, miniS = <miniS number>, port = <port number> due to

BE/BI port fault.

Probable Cause

Indicates a fault on the chip and that all ports on the chip have been disabled.

Recommended

Action

No action is required.

Severity

CRITICAL

BL-1038

Message

<timestamp>, [BL-1038], <sequence-number>,, CRITICAL, <system-name>, Inconsistent

FPGA image version detected, please restart the switch for recovery.

Probable Cause

Indicates that the FPGA image version is incompatible with the software version.

Recommended

Action

Restart the switch. If the message persists, replace the switch.

Severity

CRITICAL

BL-1039

Message

<timestamp>, [BL-1039], <sequence-number>,, CRITICAL, <system-name>, Inconsistent

FPGA image version detected, faulting the blade in slot <slot number>.

Probable Cause

Indicates that the FPGA image version is incompatible with the software version.

Recommended

Action

Power cycle the blade. If the message persists, replace the blade.

Severity

CRITICAL

BL-1041

Message

<timestamp>, [BL-1041], <sequence-number>,, CRITICAL, <system-name>, Dynamic area

mode is enabled on default switch, Faulting the blade w/ ID <Blade ID of blade

that has the mini SFP+ that does not support it> in slot <slot number> as it does

not support this mode.

Probable Cause

Indicates that the blade does not support dynamic area mode on default switch.

Recommended

Action

Turn off the dynamic area mode through Configure CLI.

Severity

CRITICAL

Advertising