514

Fabric OS Message Reference

53-1001767-01

SEC-1053

90

Severity

ERROR

SEC-1053

Message

<timestamp>, [SEC-1053], <sequence-number>,, ERROR, <system-name>, Invalid pFCS

list <pFCS list>

Probable Cause

Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.

Severity

ERROR

SEC-1054

Message

<timestamp>, [SEC-1054], <sequence-number>,, ERROR, <system-name>, Invalid FCS

list length

<list length>

Probable Cause

Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.

Severity

ERROR

SEC-1055

Message

<timestamp>, [SEC-1055], <sequence-number>,, ERROR, <system-name>, Invalid FCS

list

<WWN list>

Probable Cause

Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.

Severity

ERROR