Fabric OS Message Reference
53-1001767-01
ZONE-1022
111
ZONE-1022
Message
<timestamp>, [ZONE-1022], <sequence-number>,, INFO, <system-name>, The effective
configuration has changed to <Effective configuration name>. <AD Id>
Probable Cause
Indicates the effective zone configuration has changed to the name displayed.
Recommended
Action
Verify this zone configuration change was done on purpose. If the new effective zone configuration
is correct, no action is necessary.
Severity
INFO
ZONE-1023
Message
<timestamp>, [ZONE-1023], <sequence-number>,, INFO, <system-name>, Switch
connected to port (
<port number>
) is busy. Retry zone merge.
Probable Cause
Indicates the switch is retrying the merge operation. This usually occurs if the switch on the other
side of the port is busy.
Recommended
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
INFO
ZONE-1024
Message
<timestamp>, [ZONE-1024], <sequence-number>,, INFO, <system-name>,
<Information
message>.
Probable Cause
Indicates the cfgSave command ran successfully. The <Information message> is “cfgSave
completes successfully.”
Recommended
Action
No action is required.
Severity
INFO
ZONE-1026
Message
<timestamp>, [ZONE-1026], <sequence-number>,, INFO, <system-name>, port
<port
number>
Out of CAM entries.
Probable Cause
Indicates the total number of S_ID entries while creating or adding a zone group exceeds the limit.
Recommended
Action
If hardware zoning enforcement is preferred, edit the zoning database to have zoned PIDs for that
port.
Severity
INFO