Cvlc-1004, Cvlc-1005, Cvlc-1006 – Dell POWEREDGE M1000E User Manual
Page 200: Cvlc-1007
124
Fabric OS Message Reference
53-1001767-01
CVLC-1004
19
CVLC-1004
Message
<timestamp>, [CVLC-1004], <sequence-number>,, INFO, <system-name>, Forceful
encryption LUN removal while re-key session is still active.\nContainer: <Target
container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Probable Cause
Indicates that the encryption LUN was forcefully removed while a re-key session was still active.
Recommended
Action
No action is required.
Severity
INFO
CVLC-1005
Message
<timestamp>, [CVLC-1005], <sequence-number>,, INFO, <system-name>, There is no
LUN's found from the target.\nContainer: <Target container name>, Initiator:
<Initiator physical WWN>, LUN ID: <LUN ID>.
Probable Cause
Indicates that there are no LUNs found from the target-initiator pair.
Recommended
Action
No action is required.
Severity
INFO
CVLC-1006
Message
<timestamp>, [CVLC-1006], <sequence-number>,, INFO, <system-name>, Duplicate LUN
serial number <LUN SN> found.\nContainer: <Target container name>, Initiator:
<Initiator physical WWN>.
Probable Cause
Indicates that there is more than one LUN serial number discovered from the same target.
Therefore, encryption on this target is disabled.
Recommended
Action
No action is required.
Severity
WARNING
CVLC-1007
Message
<timestamp>, [CVLC-1007], <sequence-number>,, ERROR, <system-name>, Removal of
encryption LUN is not allowed when decrypt of existing data is
enabled.\nContainer: <Target container name>, Initiator: <Initiator physical >,
LUN ID: <LUN ID>.
Probable Cause
Indicates that there has been an attempt to remove the encryption LUN while decryption of existing
data is still enabled.