Fcr-1012, Fcr-1013, Fcr-1015 – Dell POWEREDGE M1000E User Manual
Page 294: Fcr-1016
218
Fabric OS Message Reference
53-1001767-01
FCR-1012
34
FCR-1012
Message
<timestamp>, [FCR-1012], <sequence-number>,, INFO, <system-name>, FC Router
fabric build completed on port <port number>.
Probable Cause
Indicates that the fibre channel router has completed a fabric build at the specified port.
Recommended
Action
No action is required.
Severity
INFO
FCR-1013
Message
<timestamp>, [FCR-1013], <sequence-number>,, INFO, <system-name>, Phantom FSPF
database exchange completed on port <port number>.
Probable Cause
Indicates that the specified EX_Port has completed the fabric shortest path first (FSFP) database
exchange.
Recommended
Action
No action is required.
Severity
INFO
FCR-1015
Message
<timestamp>, [FCR-1015], <sequence-number>,, INFO, <system-name>, New EX_Port or
VEX_Port added on port <port number> in domain <domain ID>.
Probable Cause
Indicates that an EX _Port was created on the specified port in the specified domain.
Recommended
Action
No action is required.
Severity
INFO
FCR-1016
Message
<timestamp>, [FCR-1016], <sequence-number>,, INFO, <system-name>, FCR fabric no
longer reachable at port id <port number> (<port number (hex)>) fabric ID <fabric
ID>.
Probable Cause
Indicates that a fabric is no longer accessible through the backbone fabric. This may be caused by
a link or switch failure.
Recommended
Action
No action is required.
Severity
INFO