Fabric OS Message Reference

437

53-1001767-01

MS-1005

69

Severity

INFO

MS-1005

Message

<timestamp>, [MS-1005], <sequence-number>,, ERROR, <system-name>, MS Invalid CT

Response from d=

<domain>

Probable Cause

Indicates the management server (MS) received an invalid common transport (CT) response from
the switch domain. MS expects either a CT accept IU or a reject IU; the MS received neither
response, which violates the Fibre Channel Generic Services (FS-GS) specification.

Recommended

Action

Check the integrity of the FC switch at the specified domain. It is not sending correct MS
information as defined by the FC-GS standard.

Severity

ERROR

MS-1006

Message

<timestamp>, [MS-1006], <sequence-number>,, ERROR, <system-name>, MS Unexpected

iu_data_sz=

<number of bytes>

Probable Cause

Indicates the management server (MS) received an information unit (IU) data of unexpected size.
The IU payload and the IU size might be inconsistent with each other or with the command that is
currently being processed.

Recommended

Action

Wait for a few minutes and retry the operation.

If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.

Severity

ERROR

MS-1008

Message

<timestamp>, [MS-1008], <sequence-number>,, ERROR, <system-name>, MS Failure

while initializing

<action>

Probable Cause

Indicates the management server (MS) failed while initializing the specified action.

The following actions might be displayed:

<while writing to ms_els_q>
MS is unable to write a message to the MS Extended Link Service Queue.

<while inserting timer to timer list>
MS is unable to add a timer to a resource.

Recommended

Action

This message is often transitory.

If the error persists, check the available memory on the switch using the memShow command.

Severity

ERROR