CVLC-1011

19

CVLC-1011

Message

<timestamp>, [CVLC-1011], <sequence-number>,, ERROR, <system-name>, Third party

license is required for encryption LUN in third party mode.\nContainer: <Target

container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.

Probable Cause

Indicates that the encryption LUN is configured with non-Brocade mode but there is no valid
license.

Recommended

Action

Obtain license for non-Brocade mode.

Severity

ERROR

CVLC-1012

Message

<timestamp>, [CVLC-1012], <sequence-number>,, ERROR, <system-name>, Disk metadata

is in wrong format (<Metadata format found (Brocade/Third party)>).\nContainer:

<Target container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.

Probable Cause

Indicates that the metadata found on the disk LUN is in the wrong format.

Recommended

Action

Use cryptocfg command to change the LUN's metadata mode.

Severity

ERROR

CVLC-1013

Message

<timestamp>, [CVLC-1013], <sequence-number>,, ERROR, <system-name>, Unable to

retrieve key record from the key archive.\nContainer: <Target container name>,

Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.

Probable Cause

Indicates that the encryption engine is unable to retrieve the key record base on the key ID found in
the metadata.

Recommended

Action

No action is required.

Severity

ERROR

CVLC-1014

Message

<timestamp>, [CVLC-1014], <sequence-number>,, ERROR, <system-name>, Missing Key

ID from user input.\nContainer: <Target container name>, Initiator: <Initiator

physical WWN>, LUN ID: <LUN ID>.

Probable Cause

Indicates that the data state in the LUN configuration is in the encrypted state without a key ID and
there is no metadata found on the LUN.