Fcr-1073, Fcr-1074, Fcr-1075 – Dell POWEREDGE M1000E User Manual

Page 309

Advertising
background image

Fabric OS Message Reference

233

53-1001767-01

FCR-1073

34

FCR-1073

Message

<timestamp>, [FCR-1073], <sequence-number>,, INFO, <system-name>, Switch with

domain ID <domain ID> in fabric <fabric ID> has lower limit of LSAN Zones

supported.

Probable Cause

Indicates that an earlier version of the switch in the backbone or edge that supports a different
limit of logical storage area network (LSAN) zones was detected.

Recommended

Action

Use the fcrResourceShow command on all Fibre Channel Routers in the Meta-SAN to find the
lowest supported LSAN zone limits. Ensure that total number of LSAN zones in the Meta-SAN are
within the lowest supported limit of LSAN zones.

Severity

INFO

FCR-1074

Message

<timestamp>, [FCR-1074], <sequence-number>,, ERROR, <system-name>, HA sync lost

as remote CP supports only <LSAN count> LSAN Zones.

Probable Cause

Indicates that the remote control processor (CP) has older firmware, which only supports a lower
number of logical storage area network (LSAN) zones. This is causing the loss of the
high-availability (HA) sync.

Recommended

Action

Keep the number of LSAN Zones to the lower limit of the two CPs or upgrade the remote CP.

Severity

ERROR

FCR-1075

Message

<timestamp>, [FCR-1075], <sequence-number>,, ERROR, <system-name>, Zone Name

configuration is larger than <Zone Name Limit> characters in the edge fabric

connected to port <port numer>.

Probable Cause

Indicates that the zone name configuration size created in the connected fabric exceeds the
maximum supported by the FC Router. This size is equal to the total number of characters used by
all the zone names in the edge fabric zoning database.

The limit includes both logical storage area network (LSAN) and Non-LSAN zone names defined in
zoning name database of the edge fabric.

Recommended

Action

Limit the zone configuration size in the edge fabric connected to this port by either reducing
number of zones or changing the zone names to smaller names.

Severity

ERROR