Cvlm-1009, Cvlm-1010, Cvlm-1011 – Dell POWEREDGE M1000E User Manual
Page 211: Cvlm-1012
Fabric OS Message Reference
135
53-1001767-01
CVLM-1009
20
Recommended
Action
Check the ISL port connected to the fabric.
Severity
WARNING
CVLM-1009
Message
<timestamp>, [CVLM-1009], <sequence-number>,, INFO, <system-name>, The member <EE
node WWN><EE slot num> of HAC <HAC name> is in the fabric.
Probable Cause
Indicates that the member of HAC is found in the fabric.
Recommended
Action
No action is required.
Severity
INFO
CVLM-1010
Message
<timestamp>, [CVLM-1010], <sequence-number>,, WARNING, <system-name>, The IP
address of EE <EE node WWN><EE slot num> IO link is not configured.
Probable Cause
Indicates that the EE IO link IP address is not configured.
Recommended
Action
Configure the EE IO link IP address.
Severity
WARNING
CVLM-1011
Message
<timestamp>, [CVLM-1011], <sequence-number>,, INFO, <system-name>, The HAC
failover occurs at EE <EE node WWN><EE slot num>.
Probable Cause
Indicates that the HAC failover occurs at the EE.
Recommended
Action
No action is required.
Severity
INFO
CVLM-1012
Message
<timestamp>, [CVLM-1012], <sequence-number>,, INFO, <system-name>, The HAC
failback occurs at EE <EE node WWN><EE slot num>.
Probable Cause
Indicates that the HAC failback occurs at the EE.