Fabric OS Message Reference

53-1001767-01

IPS-1005

54

Probable Cause

Indicates that configured Port Mode is different from the intended use.

Recommended

Action

Change the port configuration (by deleting configured FCIP tunnels or iSCSI sessions) to return the
port mode to neutral before attempting to configure the port for a different mode or use.

Severity

WARNING

IPS-1005

Message

<timestamp>, [IPS-1005], <sequence-number>,, WARNING, <system-name>, Tunnel

Authorization Failure for slot (<slot>) port(ge<port>) tunnel ID(<tunnel number>)

reason (<reason>)

Probable Cause

Indicates that tunnel setup failed because of an authorization failure from the remote side. A
reason for such a failure could be a WWN mismatch.

Recommended

Action

Change the tunnel configuration on one side of the tunnel to authorize the remote side to set up
the tunnel.

Severity

WARNING

IPS-1006

Message

<timestamp>, [IPS-1006], <sequence-number>,, WARNING, <system-name>, Tunnel

Configuration Mismatch for slot (<slot>) port(<port>) tunnel ID(<tunnel number>)

reason (<reason>)

Probable Cause

Indicates that tunnel setup failed because of a configuration mismatch between the two ends. The
reason for such a mismatch could be a Compression setting or WanTOV enforcement.

Recommended

Action

Change the tunnel configuration on one side of the tunnel to match that of the other side to set up
the tunnel.

Severity

WARNING