Fabric OS Message Reference

53-1001767-01

EM-1033

22

Probable Cause

Indicates that the environmental monitor (EM) has found a switch blade that is inserted, but the
ejector switch is not closed. The blade in the specified slot is treated as not inserted.

Recommended

Action

Close the ejector switch (raise the slider in most blades, or completely screw in the upper
thumbscrew for the FC4-48 port blade) if the field-replaceable unit (FRU) is intended for use. Refer
to the appropriate hardware manual for instructions on inserting the switch blades.

Severity

ERROR

EM-1033

Message

<timestamp>, [EM-1033], <sequence-number>,, ERROR, <system-name>, CP in

<FRU Id>

set to faulty because CP ERROR asserted

Probable Cause

Indicates that the standby control processor (CP) has been detected as faulty. The High Availability
(HA) feature will not be available. This message occurs every time the other CP reboots, even as
part of a clean warm failover. In most situations, this message is followed by the EM-1047
message, and no action is required for the CP; however, you might want to find out why the failover
occurred.

Recommended

Action

If the standby CP was just rebooted, wait for the error to clear (run slotShow to determine if it has
cleared). Watch for the EM-1047 message to verify that this error has cleared.

If the standby CP continues to be faulty or if it was not intentionally rebooted, check the error logs
on the other CP (using the errDump command) to determine the cause of the error state.

Try reseating the field-replaceable unit (FRU). If the message persists, replace the FRU.

Severity

ERROR

EM-1034

Message

<timestamp>, [EM-1034], <sequence-number>,, ERROR, <system-name>, <FRU Id> set to

faulty, rc=<return code>.

Probable Cause

Indicates that the specified field-replaceable unit (FRU) has been marked as faulty for the specified
reason.

Recommended

Action

Try reseating the FRU.

Run the systemVerification command to verify that the switch does not have hardware problems. To
run this command root access is required. Refer to the Fabric OS Command Reference for more
information on this command.

If the message persists, replace the FRU.

Severity

ERROR