Fabric OS Message Reference

107

53-1001767-01

CNM-1041

16

Recommended

Action

No action is required.

Severity

INFO

CNM-1041

Message

<timestamp>, [CNM-1041], <sequence-number>,, INFO, <system-name>, Updating

persistent Cluster DB, please avoid powering off the switch.

Probable Cause

Indicates the system is updating the persistent database.

Recommended

Action

No action is required.

Severity

INFO

CNM-1042

Message

<timestamp>, [CNM-1042], <sequence-number>,, INFO, <system-name>, Done, updating

persistent Cluster DB.

Probable Cause

Indicates that the update of the persistent database is complete.

Recommended

Action

No action is required.

Severity

INFO

CNM-1043

Message

<timestamp>, [CNM-1043], <sequence-number>,, ERROR, <system-name>, Received HBT

from undefined node IpAddress [<ip>], WWN [<wwn>]. Possible configuration error.

Probable Cause

Indicates that the remote node's WWN might be changed.

Recommended

Action

No action is required.

Severity

ERROR

CNM-1044

Message

<timestamp>, [CNM-1044], <sequence-number>,, ERROR, <system-name>, Cluster Create

Failed as the Certificate files not found, Please do the initnode.

Probable Cause

Indicates that the initnode is not invoked.