Fabr-1016, Fabr-1017, Fabr-1018 – Dell POWEREDGE M1000E User Manual
Page 256: Fabr-1019
180
Fabric OS Message Reference
53-1001767-01
FABR-1016
26
FABR-1016
Message
<timestamp>, [FABR-1016], <sequence-number>,, WARNING, <system-name>, ficonMode
is enabled.
Probable Cause
Indicates that FICON mode is enabled on the switch through a user interface command.
Recommended
Action
No action is required.
Severity
WARNING
FABR-1017
Message
<timestamp>, [FABR-1017], <sequence-number>,, WARNING, <system-name>, ficonMode
is disabled.
Probable Cause
Indicates that FICON mode is disabled on the switch through a user interface command.
Recommended
Action
No action is required.
Severity
WARNING
FABR-1018
Message
<timestamp>, [FABR-1018], <sequence-number>,, WARNING, <system-name>, PSS
principal failed (<reason for not becoming the principal switch>: <WWN of new
principal switch>).
Probable Cause
Indicates that a failure occurred when trying to set the principal switch using the fabricPrincipal
command. The message notifies you that the switch failed to become the principal switch because
of one of the following reasons:
•
The switch joined an existing fabric and bypassed the F0 state.
•
The fabric already contains a principal switch that has a lower world wide name (WWN).
Recommended
Action
Make sure that no other switch is configured as the principal switch. Force a fabric rebuild by using
the switchDisable and switchEnable commands.
Refer to the Fabric OS Command Reference for more information about the fabricPrincipal
command.
Severity
WARNING
FABR-1019
Message
<timestamp>, [FABR-1019], <sequence-number>, FFDC, CRITICAL, <system-name>,
Critical fabric size (<current domains>) exceeds supported configuration
(<supported domains>).