Fabric OS Message Reference

53-1001767-01

FABR-1016

26

FABR-1016

Message

<timestamp>, [FABR-1016], <sequence-number>,, WARNING, <system-name>, ficonMode

is enabled.

Probable Cause

Indicates that FICON mode is enabled on the switch through a user interface command.

Recommended

Action

No action is required.

Severity

WARNING

FABR-1017

Message

<timestamp>, [FABR-1017], <sequence-number>,, WARNING, <system-name>, ficonMode

is disabled.

Probable Cause

Indicates that FICON mode is disabled on the switch through a user interface command.

Recommended

Action

No action is required.

Severity

WARNING

FABR-1018

Message

<timestamp>, [FABR-1018], <sequence-number>,, WARNING, <system-name>, PSS

principal failed (<reason for not becoming the principal switch>: <WWN of new

principal switch>).

Probable Cause

Indicates that a failure occurred when trying to set the principal switch using the fabricPrincipal
command. The message notifies you that the switch failed to become the principal switch because
of one of the following reasons:

The switch joined an existing fabric and bypassed the F0 state.

The fabric already contains a principal switch that has a lower world wide name (WWN).

Recommended

Action

Make sure that no other switch is configured as the principal switch. Force a fabric rebuild by using
the switchDisable and switchEnable commands.

Refer to the Fabric OS Command Reference for more information about the fabricPrincipal
command.

Severity

WARNING

FABR-1019

Message

<timestamp>, [FABR-1019], <sequence-number>, FFDC, CRITICAL, <system-name>,

Critical fabric size (<current domains>) exceeds supported configuration

(<supported domains>).

Advertising